Personnel detection system interface protection design and component selection
Deutsch
7days a week from 9:00 am to 9:0pm
+86 18016225001

Shanghai Leiditech上海雷卯电子科技有限公司是专业的静电保护元件厂家,TVS二极管供应商;专业提供防雷防静电方案,电磁兼容EMC免费测试等服务,品质保证,库存充足,型号齐全,值得信赖,如有采购静电保护元件,TVS二极管需求,请联系雷卯,24小时服务热线:021-50828806.

By LEIDITEC | 19 November 2026 | 0 Bemerkungen

Personnel detection system interface protection design and component selection

I. What often fails is not the sensor, but the interface

 

During the autumn-winter transition, the same phenomenon often appears in maintenance records: the people-counting equipment at the entrance suddenly loses connection or counts erratically. Upon disassembly and inspection, the sensor and main control chip are intact, and the failure points are concentrated at the interfaces—human body static electricity poured into the MCU pins the moment a button was pressed, induced surges coupled through long-distance network cables broke down the powered port, and outdoor branch cables brought lightning-induced surges into the bus.

Personnel detection systems are used to detect the entry, exit, or presence of people in a specific area, undertaking safety monitoring and people-counting statistics. They are installed in crowded corridors, entrances and exits, and elevator lobbies, operating continuously over long periods. Human contact, live plug/unplug, and long-line coupling expose every external port to ESD and surges. In field repairs, algorithm misjudgments are the minority; interface failures are the majority. Doing protection upfront—the cost of a few components—is far lower than later operation and maintenance.

II. Viewing the protection device locations from the protection block diagram

The figure below shows a protection block diagram of a typical personnel detection system: the power supply is divided into two paths—12/24V DC and PoE; the signal chain covers wired interfaces, wireless interfaces, personnel counting analog front-end, motion detection, digital processing, and input/output user interface. The orange ESD markers in the figure indicate the recommended locations for placing protection devices—every external port and board-to-board connection point.

 

Personnel detection system protection block diagram

By stress type, these locations can be classified into three categories: power supply and long-line ports are selected by energy, using high-power TVS and gas discharge tubes to discharge surges; human-machine contact locations are selected by discharge level, using ESD devices to meet IEC 61000-4-2; high-speed and analog links are selected by junction capacitance, avoiding the protection device itself degrading the signal.

III. Supply side: 48V PoE input and secondary power

This solution is used for outdoor PoE Ethernet port surge protection. Leiditech adopts two-stage protection for reliable operation, ensuring signal integrity at high temperatures. It meets IEC 61000-4-2 Level 4, with contact discharge 30kV and air discharge 30kV. IEC 61000-4-5 10/700μs, 40Ω, 4kV, ±5 times. The LMBJ58CP4 is specifically designed for PoE 48V power supply. This solution ensures no packet loss during high-temperature transmission. It not only ensures no false triggering within the 48V fluctuation range, but also limits the transient amplitude to a range that the downstream stage can withstand.

 

PoE power port surge protection solution

After the 48V is converted by DC/DC, the 12V and 5V rails are graded by power: for 12V, use SMAJ15CA in parallel with PPTC (HL30-300) in seriesin parallel, with PPTC (HL30-300) in series for overcurrent protection, and low-VF Schottky SS34LVFA for reverse polarity protection; for the 5V logic power supply, use PTVS0542H100 (105A) to address both ESD and surge.

IV. Wired side: RS485 bus

Multiple terminals and gateways are often networked via RS485. The transceiver pins have limited withstand voltage, and long-line surges and enclosure ESD both strike the A/B lines. The SM712 uses a 7V/12V bidirectional structure, precisely covering the RS485 common-mode range, with 45pF junction capacitance and 17A withstand capability, meeting ±30kV; for cost-sensitive applications, SM05 (5V unidirectional, 12A) can be used. For models that retain an RS232 debug port or connect to an access control host, select SMC12 (12V bidirectional, 45pF, 15A) for the TX/RX lines.

 

RS485 differential bus ESD protection solution

V. Sensing side: analog front-end and motion detection

The personnel counting analog front-end and motion detection channels (PIR, millimeter-wave, image modules) have small output amplitudes and high gain. The protection devices must clamp quickly while not introducing junction capacitance or leakage current. The balance point is to push junction capacitance below 1pF: use USRV05-4 (5V unidirectional, 0.5pF, four-channel) for multiple inputs, and ULC0542C (5V bidirectional, 0.3pF) for a small number of channels. The DFN1006 package can be placed near the sensor connector. The sensor's digital signal lines (interrupt, configuration) are not sensitive to capacitance, so ESD0521CH (5V bidirectional, 15pF, 9A) is sufficient.

 

Analog video and sensor front-end ESD protection solution

VI. Wireless side: WiFi and NB-IoT antennas

The antenna port is directly exposed outside the device enclosure. The RF chain has the most stringent requirements for junction capacitance; above 2.4GHz, every additional 0.1pF affects VSWR and transmit power, so ultra-low capacitance devices are always used: for 3.3V systems, select ULC3311CDN (0.45pF); for 5V systems, select ULC0511CDN30 (0.22pF), both meeting ±30kV. For equipment near exterior walls or rooftops, connect a GDT (SMD4532-090NF, 2kA) in series before the ESD device to form two-stage protection.

 

NB-IoT antenna ESD and surge protection solution

VII. Human-machine side: buttons and general signals

Buttons are the most frequently touched components by the human body. Failures are concentrated in the dry autumn and winter seasons and are difficult to reproduce. The core of selection is the discharge level: for 3.3V systems, use ESDA33CP30 (15pF, ±30kV, 8A); for 5V systems, use ESDA05CP30; when board space is constrained, use the DFN0603 package ESD0521CH. For grouped GPIOs, use the four-channel SDA05W5 (5V unidirectional, 30pF, 3A) to save area. For TTL signal lines with higher current requirements, use SMDA05CCN (5V bidirectional, 60pF, 30A).

 

Button and switch signal ESD protection solution

Debug UART, download ports, and screen flex cables are often routed out to the enclosure, making them de facto external interfaces. Use ESDA33CP30 or the low-capacitance ULC3311CDN for UART; use SMC12 for on-board I2C/SPI, and add digital isolation for cross-board connections to cut ground loops; the JTAG download port is frequently hot-plugged, so use the four-channel ESDA3.3CW-4 (13pF, 2.5A) to cover it. Select MIPI screens by rate: use ULC3304P10 (0.6pF, four-channel) for medium and low speeds, and switch to ULC3304P10LV (0.28pF) for high-speed screens; the packages are compatible, facilitating model switching.

Selection master table

Interface

Typical Application

Recommended Model

Key Parameters

Package

48V PoE input

Powered-end bus clamping

SM15T68CA

VRWM 58V / Vc 103V / 14.6A

SMC

48V PoE input

Outdoor lightning protection 6kV

LM1K58CC

58V bidirectional / 2kV (8/20µs)

SMC

48V PoE input

Outdoor lightning protection 4kV

LMBJ58CP4

58V bidirectional / 3kW / 50A

SMB

48V DC bus

DC 48V surge

SMDJ58CA

58V / 3000W / 32.1A

SMC

Ethernet data lines

Ethernet port differential pair (four-channel)

SLVU2.8-4

2.8V / 2pF / 30A

SOP-8

Ethernet data lines

Ethernet port single-channel low capacitance

GBLC03C

3.3V / 0.6pF / 20A

SOD-323

12V secondary power

Output surge

SMAJ15CA

15V / 400W / 16.4A

SMA

5V logic power

Power port

PTVS0542H100

5V / 190pF / 105A

DFN1006

RS485 bus

Differential A/B lines

SM712

7V/12V bidirectional / 45pF / 17A

SOT-23

RS232 serial port

TX / RX lines

SMC12

12V bidirectional / 45pF / 15A

SOT-23

Sensor front-end

Analog input (four-channel)

USRV05-4

5V unidirectional / 0.5pF / ±20kV

SOT-23-6

Sensor front-end

Analog input (single-channel)

ULC0542C

5V bidirectional / 0.3pF / ±25kV

DFN1006-2

Sensor I/O

Digital signal lines

ESD0521CH

5V bidirectional / 15pF / 9A

DFN0603

Wireless antenna

3.3V RF front-end

ULC3311CDN

3.3V bidirectional / 0.45pF / 4A

DFN1006-2

Wireless antenna

5V RF front-end

ULC0511CDN30

5V bidirectional / 0.22pF / 5A

DFN1006-2

Wireless antenna

Primary surge (GDT)

SMD4532-090NF

90V bidirectional / 2kA

SMD4532

Button / switch key

3.3V button matrix

ESDA33CP30

3.3V bidirectional / 15pF / 8A

DFN1006

Button / switch key

5V button matrix

ESDA05CP30

5V bidirectional / 12pF / 8A

DFN1006

General-purpose I/O

GPIO (four-channel)

SDA05W5

5V unidirectional / 30pF / 3A

SOT-353

TTL signal

TTL output lines

SMDA05CCN

5V bidirectional / 60pF / 30A

DFN1006

I2C / SPI

On-board bus

SMC12

12V bidirectional / 35pF / 10A

SOT-23

JTAG debug port

Download port (four-channel)

ESDA3.3CW-4

Bidirectional / 13pF / 2.5A

SOT-353

MIPI display

Medium/low-speed screen (four-channel)

ULC3304P10

3.3V unidirectional / 0.6pF / 4.5A

DFN2510P10

MIPI display

High-speed screen (four-channel)

ULC3304P10LV

3.3V unidirectional / 0.28pF / 3A

DFN2510P10

If you are unsure about similar interface protection solutions, you can provide information such as interface type, signal rate, communication protocol, and board space to Shanghai Leiditech, and Leiditech will assist in providing preliminary part number selection (TVS/ESD) and layout considerations. Getting it right during the design phase can save rework from later rectification.

Keywords: ESD, TVS, electromagnetic compatibility, return path, Layout, clamping voltage, junction capacitance, hardware design, EMC rectification, circuit protection

 

Hinterlasse eine Antwort

Ihre E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind markiert. *
Name
Email
Inhalt
Verifizierungs-Schlüssel
ver_code